C-NLOPB - Canada-Newfoundland and Labrador Offshore Petroleum Board

09/24/2025 | Press release | Distributed by Public on 09/24/2025 06:55

Near Miss on the Terra Nova FPSO

On September 21, 2025 Suncor Energy Inc. reported an incident that occurred during equipment testing on the Terra Nova FPSO.

While testing the mechanical overspeed on the emergency generator, the engine fan failed. This resulted in fan debris being projected into the room where the generator was located. There were two workers in the room who were uninjured. However, assessments since the incident have confirmed there was potential for a fatality.

Immediate action was taken to secure the scene and isolate the emergency generator.

Suncor has initiated an investigation into the root cause of the incident, which the C-NLOER is monitoring.

Media Contacts:

Suncor Energy Inc. Media Relations 1-833-296-4570 [email protected] https://www.suncor.com/en-ca/contact-us

C-NLOER Lesley Rideout Director, Communications and Public Engagement (709) 725-2900 [email protected]

Incident Disclosures 2025

Date Update
Sep 24, 2025 Near Miss on the Terra Nova FPSO
Sep 9, 2025 Dropped Object on SeaRose FPSO
Jun 26, 2025 Sling Failure on the Hibernia Platform
Mar 10, 2025 Dropped Object on the SeaRose FPSO
Jan 9, 2025 Dropped Object on the Hebron Platform
Jan 8, 2025 Helicopter Return to Base
C-NLOPB - Canada-Newfoundland and Labrador Offshore Petroleum Board published this content on September 24, 2025, and is solely responsible for the information contained herein. Distributed via Public Technologies (PUBT), unedited and unaltered, on September 24, 2025 at 12:55 UTC. If you believe the information included in the content is inaccurate or outdated and requires editing or removal, please contact us at [email protected]